Adjusting Via DGP2 Mode
In module programming mode, enter section
[002] and use the arrow keys to scroll a 3-digit
value between 000 and 010.
Viewing Sensitivity Settings
Remove the cover to view how many times the
LED flashes, then adjust the setting
accordingly. The LED flashes a consecutive
amount of times to show the setting. Thus if
the sensitivity is set to 6, the LED flashes 6
times. Refer to the table on the back cover.

Walk-testing

At 20°C (68°F), at lowest sensitivity setting and in
Single Edge Processing mode, you should not
be able to cross more than one complete zone
(consisting of 2 beams, left and right sensor
detecting elements) in the coverage area with
any kind of movement; slow/fast walking or
running.
At the highest sensitivity setting, the amount of
movement required to generate an alarm is
doubled. The approximate width of a full beam at
11m (35ft) from the detector is 1.8m (6ft). To
walk-test, move across the detection path, not
toward the detector.