5. Enter the 3-digit [
program.
6. Turn the desired option on/off or key in the
required data.
The detector keeps the last settings in
memory even after it has been powered
down, regardless of whether its settings
were modified via Module Programming
Mode or the DIP switches and trim pot.

Single or Dual Edge Processing

This option determines the DSP (Digital Signal
Processing) of the detector. Single Edge
Processing should be used in normal
environments with minimal sources of
interference. Dual Edge Processing provides
better false alarm rejection if the detector is
placed near sources of interference that can
adversely affect it. Refer to the table on the back
cover.

LED Setting

This option enables or disables the LED. The
LED illuminates for 5 seconds when the unit
detects a movement signal that reaches the
required energy levels for an alarm and flashes if
it detects a signal that does not match the
characteristics of an alarm (non-movement
signals). Refer to the table on the back cover.

Movement Signal Indication

When this option is enabled and the detector
detects a signal that matches the characteristics
] you wish to