Installation

At the recommended height of 2.1m (7ft) to 2.7m
(9ft) ± 10%, Digigard DG85 provides full
coverage from 1.5m (5ft) to 11m (35ft) as shown
in Figure 4 on page 29. The Digigard DG85
includes a weatherproof casing so it can be
installed outside.
Avoid placing the detector within proximity of the
following sources of interference such as direct
sunlight, reflective surfaces and moving cars.
Do not touch the sensor surface as this
could result in a detector malfunction. If
necessary, clean the sensor surface using
a soft cloth with pure alcohol.
After selecting the detector's location, drill or
punch out holes for the screws (Figure 3 on page
28).

PCB Height Adjustment

The DG85 is designed for optimal performance
at a height of 2.1m (7ft), but can be installed
lower or higher. After you have installed the
detector, ensure that the adjustable height
markings on the upper right of the PCB's cover
inside the unit match the installation height.
For example, if the detector is installed at a
height of 2.1m (7ft), the PCB should then be
adjusted to 2.1m (7ft). Align the desired marking
2 Digigard DG85

Publicité

Table des Matières
loading

Table des Matières