This moisture measuring device is a sensitive tool. This means that the measurement results may
be subject to slight deviations when someone touches the device with their hand or when contact
!
is broken between the device and the material being measured. However, contact with the user's
hand forms the basis for calibrating the measuring device, so we recommend holding onto the
device whilst taking your measurements.
Die Funktion und die Betriebssicherheit ist nur dann gewährl eistet, wenn das Messgerät im Rahmen
!
der angebenen klimatischen Bedingungen betrieben wird und nur für die Zwecke eingesetzt wird,
für die es konstruiert wurde. Die Beurteilung der Messergebnisse und die daraus resultierenden
Maßnahmen liegen in der Verantwortung des Anwenders, je nach der jeweiligen Arbeitsaufgabe.
Technical data
Measurement principle
Material characteristics
Measurement range/Accuracy
Permissible operating temperature
Permissible storage temperature
Permissible max. relative humidity
Power supply
Battery service life
Automatic switch-off
Technical revisions reserved. 04.10
EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal
according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: www.laserliner.com/info
Impedance measuring principle via integrated rubber electrodes
6 building materials characteristics
56 wood characteristics
Cement screed: 0% ... 4.5% / ± 0.5%
Anhydrite screed: 0% ... 3.1% / ± 0.5%
Plaster: 0% ... 9% / ± 0.5%
Aerated concrete: 0% ... 48% / ± 1%
Concrete: 0% ... 5% / ± 0.5%
Lime malm brick: 0% ... 10% / ± 0.5%
Wood: 0% ... 60% / ± 2% (6% ... 30%)
0 ... 40°C
-10°C ... 60°C
85%
1 x 6LR61 9 V
14 h continuous measurement
After 2 min.
MoistureMaster
13
GB

Publicité

loading

Ce manuel est également adapté pour:

082.033a