Confi guration menu
9-
Lights groups available
0
1
...
4
5
10-
Louver presence
No
Ye
11-
Unit's remote ID
A
1
2
3
...
7
12-
HVAC system
Ye
No
Confi guration menu – Supplement
Item 4- - Item 5-:
The user desired temperature can be set through buttons F or D.
Temperature increase or decrease starts from the factory-set value
of 22C (72F).
Each time button F or D is pressed, temperature is increased or
decreased by ±0.5 degrees (or ±1F).
In this case the temperature range is between 20 C and 24C (68F
to 76F). In any case, the user can increase this temperature range
by changing item 4 and 5 values.
Item 4 is the starting temperature and item 5 is the value to be as-
signed each time button F or D is pressed.
There follow some examples according to the scale range required
(we suggest changing item 5 ONLY):
GB - 6
There is no lights/groups to control: no icons
will be displayed
Just one lights group is available: "1" group icons
will not be illuminated
...
Four lights groups are available: "Lamp" and "4"
groups icons will be illuminated
There is no group, but user can manage the light
[Defaults: "0" Lights control disabled.]
Some units doesnʼt have the louver installed. This item
consents to donʼt show the louver icon on the LCD
None
Louver installed (Stepper motor or
Synchronous motor + home position)
[Defaults: "No" No louver presence.]
Unit remote ID ALL
Unit remote ID 1
Unit remote ID 2
Unit remote ID 3
...
Unit remote ID 7
[Defaults: "A" All]
Some application needs to manage just the power
module, without any other system linked
An HVAC system is present
An HVAC system is NOT present
[Default: "Ye": HVAC system is present]
Item 5 = 2C (4F)
Minimum temp. = 14C (56F) —> automatically set at 15C (59F)
Maximum temp. = 30C (88F)
Item 5 = 1.5C (3F)
Minimum temp. = 16C (60F)
Maximum temp. = 28C (84F)
Item 5 = 1C (2F)
Minimum temp. = 18C (64F)
Maximum temp. = 26C (80F)
The user can also set the value of item 4 so that no temperature in-
crease or decrease can change it when button F or D is pressed.
To do so, set the desired fi xed temperature value in item 4 and set
0C (0F) in item 5.
Anyway, the desired maximum temperature value is 32C (90F).
YES: Once the Lights Menu
is selected, the groups icon
will be energized on the lcd
(no icons if just one group is
selected)
"A" and "1" icons are
energized in the light
menu.User can manage
all lights or just one