Initial commissioning

An automatic commissioning programme is run before
inserting or filling the active carbon filter and nozzle
cleaner. This programme lasts 2–9 minutes.
Putting the WC into operation
Prerequisites
• Spray shield is positioned on the WC seat
1
Open the maintenance opening.
2
Press and hold the <Shower> button (1) while
switching on the power switch (2). Wait until the
dryer arm is extended and the blue LED flashes.
Commissioning programme starts.
1
2
The commissioning programme is active as long as
the blue LED is flashing. If an error occurs, the
programme is cancelled after 9 minutes and the
red LED flashes.
If the red LED flashes, the malfunction (e.g. lack of
water) must be rectified and the commissioning
programme must be restarted.
3
Check whether the commissioning programme is
completely finished (blue LED lights up).
4
Insert the active carbon filter.
5
Remove the screw cap of the nozzle cleaner. Pull
out the filling tray. Position the nozzle cleaner on
the filling tray and fill. Do not squeeze the bottle.
1
3
2
6
Reinsert the filling tray and close the maintenance
opening.
If active carbon filters and nozzle cleaners are not
inserted or refilled, the red LED will light up.
7
Cover the IR window of the user detection with
your hand and keep it covered.
8
Check whether the <Odour extraction unit> and
<Dryer> buttons are pressed on the control panel.
If not, press both buttons. Odour extraction unit
starts.
9
Press the <Shower> button. The spray arm
extends and the shower spray starts. Increase or
lower the shower spray intensity by moving the
slider forwards <+> or backwards <->.