TROUBLESHOOTING

DISPLAY off

 Check that the power cord is correctly connected to the appliance socket and to the
mains socket.
 Check that the main switch is set to "I".
 Check the fuse. If necessary, replace with a spare 2A fuse.

ALARM MESSAGES

NO GAS BOTTLE

This message is displayed (and the red LED lights) when no pressurized gas bottle is installed
or when a gas bottle is inserted but not correctly screwed down. If the red LED lights during
operation, the gas bottle is empty and must be replaced with a new, charged bottle.
This appliance is designed to use only a single type of gas bottle authorized by the Winefit
manufacturer. Use of any other gas bottle will invalidate the warranty and can make the
appliance unsafe. The gas bottle may contain one of three types of pressurized gas, according
to need. The available gases are nitrogen, argon, and an argon + carbon dioxide mixture.

INSERT WINE BOTTLE

This message is displayed (and the green LED goes out) when the wine bottle is not inserted
or is incorrectly inserted.
While this message is displayed, the keypad is inactivated.