Installation and Operating Specification FU Basic
Heat dissipation in standby opera-
tion
Output 10 V
Max. contact rating of the relay
Max. permissible ambient tempera-
ture
Min. permissible ambient tempera-
ture
Permissible temperature range for
storage and transport
Max. permissible installation height
Permissible rel. humidity
Electromagnetic compatibility for the
standard voltage 230 / 400 V ac-
cording to DIN IEC 60038
Harmonics current
Max. leakage current according to
the defined networks of
DIN EN 60990
Vibratory strength
(for vertical installation, i.e. cable
inlet down).
Max. cross section/diameter of the
conductors for line and motor con-
nection
Housing protection
* Regarding the line connection, these devices are to be classified as category "C2" according to the relevant DIN EN 61800-3
(domestic fixed installation).
The increased requirements placed on electrical interference > 2 kHz for devices of the "C1" category (domestic general) are
complied with in addition.
L-BAL-E187-GB 1703 Index 002
approx. 3 W
I
10 mA (short-circuit-proof)
max
2 A / 250 VAC
55 °C
0 °C (if mains voltage is not switched off up to -20 °C)
-30...+80 °C
0...4000 m amsl
above 1000 m amsl the rated current is to be reduced by 5 % / 1000 m
85 % no condensation
Interference emission EN 61000-6-3 (domestic household applications)
Interference immunity EN 61000-6-2 (industrial applications)
According to EN 61000-3-2 (see Electrical installation / Harmonics current)
Please ask manufacturer for the individual harmonic oscillation levels of
the current as a percentage of the fundamental oscillation of the rated
current.
FU-BS 2.5/5/8 < 3,5 mA
FU-BS 10 > 3,5 mA
FU-BS 14/16 (depending on applied mains voltage)
< 3,5 mA @ < 480 V
≥ 3,5 mA @ ≥ 480 V
Broadband noise (simulated life-endurance test) in accordance with
EN 61373, category 1 class B.
Shock test according to EN 61373, category 1
Conductor cross section single-wire 4 mm
Conductor cross-section fine-wire: 4 mm
Conductor (AWG): 12
IP54
Part.-No.
18/22
Enclosure
2
2
, with wire end ferrule 2.5 mm
2