Burner And Nozzle Specifications - SCHOLTES PP 40 DCDR F Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25

Burner and nozzle specifications

Table 1
Burner
D. Triple ring
C. Rapid
B. Semi-rapid
I. Double flame (inner DC-DR)
I. Double flame (outer DC-DR)
Supply pressure
*
At 15°C and 1013 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/kg
***
Butane
P.C.S. = 49.47 MJ/kg
Natural
P.C.S. = 37.78 MJ/m
! The hob can only be installed above built-in ovens with a cooling ventilation system.
PP 40 TC F...
PP 40 TC SF...
B PP 40TC/CS...
B B B B B
D D D D D
C C C C C
B PP 40TC...
B B B B B
D D D D D
C C C C C
Diameter
Heating power
(mm)
kW (H.s.*)
Nomin.
130
3.25
100
3.00
75
1.65
30
0.90
130
4.10
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
C C C C C
B B B B B
C C C C C
B B B B B
Liquid gas
By-pass
Nozzle
1/100
1/100
Red.
(mm)
(mm)
G30
1.3
57
91
236
0.7
40
86
218
0.4
30
64
120
0.4
30
44
1.3
57
70
298
28-30
20
PP 40 DCDR F...
PP 40 DCDR SF...
B PP 40DCDR/CS...
B B B B B
I I I I I
C C C C C
B PP 40DCDR...
B B B B B
I I I I I
C C C C C
Natural gas
Flow rate *
Nozzle
Flow rate *
g/h
1/100
G31
(mm)
232
124
214
116
118
96
65
64
70
293
110
37
25
35
45
C C C C C
B B B B B
C C C C C
B B B B B
GB
GB
GB
GB
GB
l/h
G20
309
286
157
86
390
20
17
25
19

Publicité