Mounting; Mounting The Sensor - Balluff BOD 26K LB04-S115-C Instructions De Service Et De Montage

Capteur de distance
Masquer les pouces Voir aussi pour BOD 26K LB04-S115-C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dimensions of light spot
11
X
8,5
Illustr. 4
15500269
5

Mounting

5.1
Dimensional drawing
5.2

Mounting the sensor

Sensor alignment
Position sensor and screw to suitable holder, e.g. Typ BOS 26-HW-1* (not included in standard delivery), via fixing
holes.
*Part number: see list of accessories
INFORMATION
Observe the following operating conditions:
• The distance to the object must be within the sensor's operating range (see technical data).
• The direction of movement of the object should be cross-wise to the sensor's front screen
(illustr. 7+8).
• With strongly reflective or shiny surfaces, incline the sensor by approx. 5 ° in relation to the
surface of the object (illustr. 9).
CAUTION
In the case of strong vibrations (shocks / oscillations), the sensor must be given constructive
protection from damage.
46
A
B
C
BOD 26K
A
B
C
D
X
D
All dimensions in mm (typical values)
Illustr. 5
15300716
No. 834826 E Edition 1310; Replaces edition 1111; Subject to modification
Mounting and
operating instructions
-LB(R)04...
-LB(R)05...
30
80
100
300
1.5 x 3
1.5 x 3.5
1.5 x 3.25
2 x 4.5
29.4
32.5
Illustr. 6
15300065