11 Operation and maintenance

In order to avoid the hydraulic oil warming unnecessarily, switch the hydraulic power pack off as soon
as it's no longer needed.
If warm hydraulic oil is required, allow the hydraulic power pack to run against the pressure relief valve
for a while. The tank temperature can be viewed at the fill-level sight glass for the hydraulic oil.
Check the hydraulic oil fill-level from time to time and top it up if necessary.
The motor is equipped with protection against short-circuit, overload and undervoltage. However, this
does not provide any protection against touching current conducting parts. The hydraulic power pack
may therefore only be operated in electrical systems which are equipped with residual current devices.
Shut down the hydraulic power pack immediately if leaks occur during operation. Immediately remove
discharged hydraulic oil. The leak must be eliminated before the hydraulic power pack is started back
up again. Observe the instructions in the safety data sheet in the event of contact with the hydraulic oil.
The safety data sheet can be requested from the hydraulic oil manufacturer (e.g. Divinol) in the
respective country.
When draining the oil, make sure that the collecting vessel is sufficiently large.