Hydraulic power pack with load sensing variable displacement pump and constant displacement pump
Lay the electric cables such that they cannot be accidentally pulled or tripped over. Only pull on the plug
in order to remove the plug from the electric outlet.
Always remove the plug from the electric outlet before cleaning.
If you do not use a pressure filter for your applications, we recommend purifying the mineral oil before
beginning work. To do this, connect each pump outlet P to port T using a tubing line. The entire flow of
hydraulic oil is pumped through the return filter. The pumps should be operated in this way for at least
15 minutes.
When commissioning the complete equipment set for the first time, we recommend checking the
hydraulic oil fill-level frequently because all the tubing lines are initially empty.
If the diaphragm accumulator is used, replace the fitted drain hose with the longer drain hose included.
Cut the hose to the correct length.
There are two options for connecting the discharge measuring container's return hose. Replace the
plugs with the connecting sleeves and secure the return hose with a hose clamp.