Télécharger Imprimer la page

EnviroBoss EB60 Manuel Du Propriétaire page 7

Publicité

Les langues disponibles

Les langues disponibles

SYSTEM MESSAGES
The Control Panel will display the following messages based on system performance and environmental conditions. User
action, if any is required, is indicated in the third column.
C O N T R O L P A N E L
M E S S A G E
INITIALIZING
FIRMWARE VERSION
XXX
FXXX-XXX
OFF
PLEASE WAIT
COMP. DELAY XX
UNIT ON XXXX HRS
INLET XXX°F / XX%
HUMIDISTAT
INLET XXX°F / XX%
LOW TEMP
INLET XXX°F/ XX%
HI TEMP CYCLE
REMAINING XX MIN
---
DEFROST XX
WAIT FOR
DEFROST XXX
WAIT FOR
UNIT DRYING XXX
CHECK FILTER >
---
CLEAN COILS >
---
07-02330B EB60
E X P L A N A T I O N
Unit is powering up.
Indicates control board firmware version number.
Model number.
Unit has finished powering up and is operating.
60s delay before compressor turns on. Allows system
pressure to equalize.
First line: indicates total operating hours.
Second line: Toggles between inlet temperature and in-
let RH every 2 seconds.
First line: indicates unit is in humidistat mode
Second line: Toggles between inlet temperature and in-
let RH every 2 seconds.
Unit shuts off if inlet temp below 45°F/7°C. Turns back
on when inlet reaches 50°F/10°C.
Unit overload limit reached. Cool-down initiated.
Unit is defrosting, with countdown in seconds.
Unit turned off when coil is cold or already in a defrost
cycle. Proceeds to finish cycle or initiate one to clear the
coils of ice before storage.
Occurs when unit is turned off and coil is not frozen.
Clears the coils of water before storage.
Prompt to check filter.
Prompt to clean coils and interior.
7
U S E R A C T I O N
None
None
None
None
None
None
None
None
None
None
None
None
Check filter. Press the > key
to reset
Clean coils. Press the > key
to reset
EnviroBoss

Publicité

loading

Produits Connexes pour EnviroBoss EB60