Uline H-5647 Mode D'emploi
Masquer les pouces Voir aussi pour H-5647:
Les langues disponibles

Les langues disponibles

π
H-5647
STAINLESS STEEL
ROTARY DRUM PUMP
TOOLS NEEDED
1/2" Wrench
IMPORTANT! This pump is made out of 304 stainless steel and PTFE. Use liquids compatible with pump
component materials. Follow OSHA guidelines when using this pump, including proper grounding and
protective gear as required. For a full list of materials and compatible chemicals, see uline.com.
Unit not UL or FM approved.
1.
Rotate handle clockwise several times to prime. If
unit does not prime after a few turns, pouring some
fluid into pump inlet may help free pump.
2. For siphoning, position handle straight down.
3. To stop siphoning, rotate handle 1/4 turn (leave
handle in horizontal position).
PAGE 1 OF 6
1-800-295-5510
uline.com
Flathead Screwdriver
SPECIFICATIONS
Pump Type
Flow
Maximum Fluid Temperature
Bung Adapter
Suction Tube Length
Inlet
Outlet
Wetted Parts
Maximum Viscosity
OPERATING INSTRUCTIONS
Rotary – Vane
10 GPM
140°F / 60°C
2" Male
40" Maximum
1⁄" O.D.
1" O.D. Curved Spout
304 Stainless Steel, PTFE
1,000 cps
4. After using pump, position handle straight down.
Liquid will drain back into the container.
5. If pump is removed from drum, rinse it thoroughly in
a liquid that is compatible with both the pump and
the fluid being pumped.
6. Regularly check pump and suction tubes for leaks.
Leaks in the suction line or in pump housing will
cause inefficient pumping and loss of prime.
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
0721 IH-5647
Table des Matières
loading

Sommaire des Matières pour Uline H-5647

  • Page 5: Pompe À Baril Rotative En Acier Inoxydable

    Suivez les directives OSHA lors de l'utilisation de cette pompe, y compris la mise à la terre appropriée et au besoin, le port d'équipement de protection. Reportez-vous au site Web uline.ca pour consulter la liste complète des matériaux et produits chimiques compatibles. Cet article n'est pas homologué...
  • Page 6 (15). Assurez-vous que le tube du tube d'aspiration assemblé. Vissez le tube d'aspiration assemblé n'est pas obstrué et qu'il est d'aspiration assemblé dans le boîtier (3). inséré à la profondeur voulue dans le baril. 1-800-295-5510 uline.ca PAGE 6 OF 6 0721 IH-5647...

Table des Matières