opERATINg INsTRucTIoNs
G
AuToMoBILE RELAy TEsTER RT-100
ITEM No. 123472
INTENDED usE
The automobile relay tester is intended for making fast and easy checks of most current auto-
mobile relays with 4 or 5 connections. The tester performs a full automatic check of the relay
and indicates the result with a light (green = OK, red = error). The test is performed at the coil
and contact side. Only one relay can be tested at a time. Do not connect more relays.
The automobile relay tester requires an automobile direct current of 12V to operate. This can
be taken directly from the vehicle battery. Pole terminals makes connection to the vehicle
battery easy.
Any use other than that described above will damage the product and may involve other risks,
such as short-circuit, fire, electric shock. Do not change or modify any part of the product.
Observe the safety instructions!
sAfETy INsTRucTIoNs
T he warranty will be void in the event of damage caused by failure to observe
these safety instructions! we do not assume any liability for any consequen-
tial damage!
This device is not a toy and should be kept out of the reach of children.
Do not leave the packaging material lying around carelessly; it may become a dangerous toy
for children.
Do not expose the device to damp or wet.
Strong vibrations or falls can damage the device.
DEscRIpTIoN of THE pARTs
1 Power supply cable with pole terminals
(red = plus, black = minus)
2 Test socket for automobile relays
3 Display for the test result
(green= OK, red = error)
4 Press button for test start and test end
5 Selector switch for 4 PIN or 5 PIN relay
gETTINg sTARTED
Proceed as follows to test automobile relays:
• Connect both pole terminals to a source of 12V direct current. The red pole terminal must
be connected to the positive pole, and the black terminal must be connected to the negative
pole. Pay attention to the correct polarity.
• This display (3) turns red after roughly 1 second.
• Select the number of contacts on your relay on the selector switch (5). Slide the switch to
the position that corresponds to the connections on your relay (4 PIN or 5 PIN).
VERsIoN 05/14
• Plug the relay completely into the appropriate test socket (2).
• Push the press button (4) to start the test. The relay tester performs 10 functional tests in
succession, in order to be able to detect intermittent faults as well. The relay energises
audibly 10x.
• If the test was successful, the display lightens up green. If a fault was detected (relay does
not energise, contact resistance of the switch contacts too high etc.) the display lights up
red. Check the faulty relay thoroughly or replace it.
• Remove the relay. The last display status remains visible and the next relay test can be
done.
• Always disconnect the pole terminals from the voltage source after the test. Don't leave
them connected permanently.
The test result is a quick test! Due to the circuitry, it is not possible to test for all
faults, such as voltage drop on the contacts under full load etc.
If the relay tester connection is made with a relay already plugged into the supply
voltage, a test run will be done immediately. For further tests the button (4) must be
pressed.
If the relay tester has been connected with incorrect polarity, the display does not
light up and the device is inactivated. Check and correct the connection to the
supply voltage.
Make sure there is sufficient ventilation when working with lead-acid batteries.
Danger for explosive gases when charging. Avoid naked flames and sparks.
Make sure the polarity is correct when making connection and avoid short-circuits.
Pay attention to rotating parts with running engines. Danger for injury or damage to
the device.
DIsposAL
Electronic devices are recyclable waste materials and must not be disposed of in
thehousehold waste!
Dispose of unserviceable products in accordance with the relevant statutory regula-
tions.
TEcHNIcAL DATA
Operating voltage .................................10.8 – 14 V/DC
Relay - coil resistance ..........................20 – 500 Ohm
Relay - contact resistance ....................<200 Milliohm (threshold value)
Relay - test voltage ...............................9 V/DC
Length of the connecting cable .............approx. 130 cm
Dimensions (LxWxH) ............................133 x 69 x 35 (mm)
Weight ..................................................approx. 190 g
Operating conditions .............................0 to +50 °C, <80% rel. air humidity
Legal notice
G
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© copyright 2014 by conrad Electronic sE.

Publicité

loading

Ce manuel est également adapté pour:

123472