ASSEMBLY
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before carrying out any work on the tool.
Type of filter
Normal filter
► Fig.7: 1. Capsule 2. Prefilter 3. Filter
High performance filter
► Fig.8: 1. Capsule 2. High performance filter
Disposing of dust
CAUTION:
Empty the cleaner before it
becomes too full, or the suction force weakens.
CAUTION:
Be sure to empty out the dust
inside the cleaner itself. Failure to do so may
cause the filter to be clogged or the motor to be
damaged.
Disposing of dust for normal filter
1.
In order to drop dust sticking on the filter in the
capsule, tap the capsule 4 or 5 times with your hand.
Now point suction inlet downwards, turn capsule in
direction of arrow in diagram, and disconnect capsule
slowly and straight.
► Fig.9: 1. Capsule 2. Suction inlet
NOTE: Dust may spill out when capsule is opened, so
be sure to set a garbage bag beneath capsule.
2.
Remove accumulated dust from inside of capsule
and off of prefilter.
► Fig.10: 1. Prefilter 2. Capsule
3.
Twist prefilter in direction of arrow to unfasten
securing lip from cleaner unit and then pull off prefilter.
► Fig.11: 1. Prefilter 2. Securing lip
4.
Clean out fine dust from prefilter. Next, remove
filter, and lightly tap to dislodge dust.
► Fig.12: 1. Prefilter 2. Filter
Disposing of dust for high
performance filter
1.
In order to drop dust sticking on the filter in the
capsule, tap the capsule 4 or 5 times with your hand.
Now point suction inlet downwards, turn capsule in
direction of arrow in diagram, and disconnect capsule
slowly and straight.
► Fig.13: 1. Capsule 2. Suction inlet
NOTE: Dust may spill out when capsule is opened, so
be sure to set a garbage bag beneath capsule.
2.
Remove accumulated dust from inside of capsule
and off of high performance filter.
► Fig.14: 1. Capsule 2. Hign performance filter
3.
Twist high performance filter in direction of arrow
to unfasten securing lip from cleaner unit and then pull
off the filter.
► Fig.15: 1. Securing lip
4.
Clean out the fine dust and lightly tap to dislodge
dust from high performance filter.
Reassembly
Reassembly for normal filter
1.
Put on filter until it is fully in position on the cleaner
unit.
► Fig.16: 1. Filter
► Fig.17: 1. Filter
NOTE: Make sure filter is put on straight without
being peeled back. If filter is put on incorrectly as
shown in diagram, dust will get into motor housing,
and cause motor failure.
2.
Connect prefilter. At this time, make sure to twist
prefilter so that securing lip is firmly locked into cleaner
unit.
► Fig.18: 1. Prefilter
► Fig.19
3.
Connect capsule. Align O symbol on capsule with
O symbol on handle and then firmly twist capsule in
direction of arrow until it is secured.
► Fig.20: 1. O Mark
► Fig.21: 1. Handle 2. Capsule
NOTE: Always remove dust ahead of time, as suction
power will be reduced if there is too much dust in
cleaner.
NOTE: Always be sure to check that both filter and
prefilter are loaded correctly prior to using cleaner.
If they are not loaded correctly, dust will get into the
motor housing, and cause motor failure.
If the following examples occur, filter and prefilter are
not loaded correctly. Reload them correctly to rectify
problem.
Problem Examples
Example 1: Only prefilter has been loaded (no filter)
► Fig.22: 1. Prefilter
Example 2: Only filter has been loaded (no prefilter)
► Fig.23: 1. Filter
Example 3: Filter has been loaded in a peeled back
state
► Fig.24: 1. Filter
Example 4: Prefilter's securing lip is not firmly locked
into groove of cleaner housing
► Fig.25: 1. Groove of cleaner housing 2. Prefilter
3. Securing lip