at all). The 'Krois Modell' coupler is best used with a value of '48'
(4 seconds on, then completely off).
Num. Value:
CV#63 Decoupler
Trigger Values
CV#105,106 User Data: In these CVs you may save arbitrary
values for whatever need you have. The values have no kind of
influence on the working conditions of the decoder.
• CV#112 User Configuration Register 2: If activated the short
time memory keeps the decoders state for about 5 seconds in
analogue mode before reacting to changed conditions. So short
faults in the electricity supply have no effect.
Bit-No.
Bedeutung
*)
Not Used
0...4
Not Used
Short Time Memory activiated
5
Short Time Memory disabled
*) Lenz digital numbers the bits from 1 to 8.
• CV#113 Frequency of Random Events: This CV sets the
shortest time between random events. The time ranges from 32
milli-seconds (e.g. for simulating a fireplace) up to 16 seconds
(e.g. for switching on and off the light in a compartment coach).
Num. Value
0
1
2
3
4
• CV#127 Software Subversion: A read-only CV which is set by the
manufacturer. Contains additional information about the actual
software version used in the decoder (=> CV#7).

5. Error handling

Light is turned on and off when increasing DCC speed steps:
The operation modes of the light bar and the central station
are different. The latter is sending in 28 speed step mode but
the decoder estimates the 14/27 mode. Operation modes of
the decoder and the central station have to be the same for
proper a operation. You should change the decoder settings.
Select 28 speed steps by setting CV#29 to '02' or '06'.
Light is not switchable with a DCC central station:
The operation modes of the light bar and the central station
are not the same. The DCC central station is in 14/27 speed
step mode, yet the decoder makes use of the 28 speed step
mode.
Light is not switchable in Motorola® operation mode:
The light bar only 'understands' the Motorola®-II digital
encoding. Set up your central station so that it sends this
format.
When adjusting the brightness with the potentiometer the LEDs
flicker:
Increase the brightness by turning the potentiometer or attach
a buffer capacitor as flickering prevention.
The "old Arnold central station" does not read the Primary Address
(CV#1):
You can set the Primary Address (CV#1) in either case. Yet for
Decade (0x...9x)
Activation Time
(with full voltage)
Minimum Time
32 ms
64 ms
128 ms
256 ms
512 ms
Unit Position (x0...x9)
Clamp Rate
(reduced Voltage)
Num. Value
5
6
7
8
9
21
Bit
CV
Value
Value
0
0
1
32
Minimum Time
1 sec
2 sec
4 sec
8 sec
16 sec
kuehn