20
with a 'x0' for full and a 'x9' for least brightness. Use CV#59 to
switch on or off the key dependant dimming function.
Additionally you have to set a '05' to the appropriate CV#47 ...
#52. The decade of CV#55 (0x...9x) sets the cycle time of the
effects. '0x' means a cycle time of 0.5 seconds, '0x' one of 4.5
seconds.
Num. Value:
CV#55
• CV#56 User Configuration Register 1: The factory setting is '00'
witch means only the potentiometer affects the brightness of
the light bar. With a value of '01' in CV#56 dimming is done
solemnly by the CVs#57 and/or CV#60 through #62 instead. In
this case the potentiometer is disconnected internally.
Bit-No.
Bedeutung
*)
Brightness Controlled by Potentiometer
0
Brightness Controlled by CV (Pot. Off)
Not Used
1...7
Not Used
*) Lenz digital numbers the bits from 1 to 8.
• CV#57: Dimming of all LED Outputs: This CV defines the
brightness of all LEDs simultaneously. A '0' here sets the
maximum brightness, a '9' the minimal.
Num. Value:
CV#57 Dimming
all LED Outputs
• CV#59: Switchable Dim (Lower Beam): Here you specify the
function to activate the lower beam. The reduced brightness is
set in CV#55.
Bit-No.:
Num. Value:
CV#59
Lower Beam
*) Lenz digital numbers the bits from 1 to 8.
• CV#60, #61, #62 Dimming Outputs A ... F: With the values in
these CVs you may define the brightness of each output
individually. This might be appealing in a compartment coach.
As before, a '0' stands for full brightness, a '9' for minimum light.
Also the decade and the unit position have each its own
meaning: the unit position affects the outputs A, C and E while
the decade is in charge of B, D and F. An example: You want to
set B with brightness 4 and A with brightness '3'. So you have to
program a value of '43' to CV#60.
Num. Value:
CV#60
Dimming A,B
CV#61
Dimming C,D
CV#62
Dimming E,F
• CV#63 Decoupler Trigger Values: The decade of CV#63 (0x...9x)
defines the time of full activation of the electric decoupler (i.e. it
is charged with full voltage): 0=0.5 seconds, 1=1 second, ...,
9=9 seconds. The unit position (x0...x8) sets the clamp rate
(reduced voltage) after the full activation has passed: '0' means
'No Reduction', '7' = 'Maximum Reduction' (lowest clamp
voltage). A value of '8' switches the decoupler to 'Off' (no voltage
kuehn
Decade (0x...9x)
Cycle Time Effects
Decade (0x...9x)
7
6
*)
128
64
-
-
Decade (0x...9x)
Brightness Output B
(AUX 2)
Brightness Output D
(LED2, LED5)
Brightness Output F
(LED4, LED7)
Unit Position (x0...x9)
Unit Position (x0...x9)
0
LEDs (LED1 to LED7)
5
4
32
16
-
-
Unit Position (x0...x9)
manual LH10
Brightness of Lower
Beam
Bit
Value
0
1
Brightness of all
3
2
1
8
4
2
F4
F3
F2
Brightness Output A
(AUX 1)
Brightness Output C
(LED1)
Brightness Output E
(LED3, LED6)
CV
Value
0
1
0
1
F1