Bio-Reiniger
Faults
Warning! Before starting work on the cleaning table fixtures, switch off the electrics and unplug from the mains Test the
equipment to ensure the power is off!
Display
Fault
screen
Detergent cold, heating system not working
F 1
Detergent cold, heating system not working
F 2
Wash pump not working
F 3
Aerator not working
F 4
Level switch not working
F 5
Short-circuit in level switch
Detergent cold, temperature sensor not
F 6
working
F 7
Short circuit in temperature sensor
LO
Heating system and wash pump not working
30
41
>41
Overheating
Instructions for disposal
The device, accessories and packaging should be recycled in an environmentally friendly manner.
Do not throw electrical device into the household waste Compliant to European directive 2002/96/EU on used electrical and
electronic devices and their implementation within national law, electrical devices that are not longer usable must be
collected separately and recycled in an environmentally friendly manner
Herewith we, the DENIOS AG, Dehmer Straße 58-66, 32549 Bad Oeynhausen, declare that the design
of our product :
complies with the following relevant provisions: EG 2006/42/EG, 2004/108/EG, EN 349, EN 12100 -1,-2, EN 60204-1, EN 12981-1;-2.
DENIOS AG, 04.01.10
Dokumentationsbevollmächtigter
Herr Dr. Ing. R. Adenstedt
Technischer Leiter
Anschrift: s.o.
Cause
Heating system plug contacts
are loose
4. The pump is not connected or is
faulty;
5. Fuse faulty
6. Temperature limiter has been
triggered
3. The pump is not connected or is
faulty;
4. Fuse faulty
3. Aerator is not connected, or is
faulty;
4. Fuse faulty
Level switch not connected
Level switch faulty
Temperature sensor not
connected
Temperature sensor faulty
3. Fill level fallen below minimum
level
4. Float switch dirty and in the
wrong position
Energy-saving mode
Nominal temperature reached
Position of temperature sensor
Declaration of Conformity
9 / 77
Solution
Check plug contacts to ensure
connected properly.
4. Connect heating system; replace if
necessary
5. Replace fuse.
6. Have unit checked, temperature
limiter must be activated
3. Connect wash pump; replace if
necessary
4. Replace fuse.
3. Connect aerator; replace if
necessary
4. Replace fuse.
Connect level switch
Replace level switch
Connect temperature sensor
Replace temperature sensor
3. Refill with detergent
4. Clean the float-switch mechanism
Switch off energy-saving mode
Switch off device immediately!
Have device checked!
.
..............................................