9. Platforms and Control Cabinet Detail Layout
Place platforms and control cabinet as shown in Fig. 3
for surface mount or flush mount applications.
DO NOT anchor any components at this time. The
control cabinet should be located on the opposite
end of vehicle approach, as shown in Fig. 3. Operator
should be in a position to notice any misalignment of
lifting pads or vehicle during operation. Rotary Lift
does not recommend placing the control cabinet in a
different location orientation and doing so would be
the responsibility of the installer and/or end user.
OUTRIGGER CUTOUT
IMPORTANT
oriented so operator is facing the direction of the lift
when operating the lift.
If lift will be a flush mount application, the total run
length of the pipe chase from pit to bottom rear of
control cabinet should not exceed 79" (2007mm).
CONTROL CABINET PLACEMENT
DIRECTION
OF APPROACH
*23-5/8
(600mm)
*35 (890mm)
FOR TESLA
DISTANCE BETWEEN
PLATFORMS
MAXIMUM 12 FOOT (3658mm) FROM OUTRIGGER CUTOUTS,
MINIMUM 5 FOOT (1524mm) FROM OUTRIGGER CUTOUTS,
EITHER FRONT SIDE OF LIFT (HOSE SIDE)
(OPTIONS AVAILABLE FOR HOSE EXTENSIONS AND
ADDITIONAL HOSE COVERS IF EXCEED 12 FOOT (3658mm)
ENVELOPE)
10
Control cabinet should always be
*NOTE: 23-5/8" (600mm) WILL ACCOMMODATE MOST
VEHICLES. LIFT MAY BE ADJUSTED DURING
INSTALLATION BUT DISTANCE BETWEEN
PLATFORMS SHOULD NOT EXCEED 30" (762mm).
CONTROL CABINET SHOULD BE
ORIENTED SO THAT OPERATOR
FACES LIFT WHEN OPERATING
CONTROLS
OUTRIGGER CUTOUT
CONTROL CABINET PLACEMENT ENVELOPE
Fig. 3