Télécharger Imprimer la page

Rangemaster RMPE Serie Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
Connection between Hood and exterior
blower:
1. Remove the wiring box cover (A). Remove
a knockout from the wiring box.
2. Feed 6" of power cable through the knock-
out opening and secure cable to the wiring
box with an appropriate connector.
3. Make electrical connections and connect
the wires (see instructions in the exterior
blower).
4. Replace wiring box cover and screws.
Make sure that wires are not pinched
between cover and box.
WIRING BOX FOR
THE ELECTRICAL
CONNECTION
Electrical connections:
1. Remove the wiring box cover (B). Remove
a knockout from the wiring box.
2. Feed 6" of power cable through the knock-
out opening and secure cable to the wiring
box with an appropriate connector.
3. Make electrical connections. Connect
white to white, black to black and green to
green.
4. Replace wiring box cover and screws.
Make sure that wires are not pinched
between cover and box.
WIRING BOX FOR
THE EXTERIOR
BLOWER
- 6 -
Connection the hood to the
exterior blower
Exterior blower
WIRING BOX
COVER (A)
WIRING BOX
COVER (B)

Publicité

loading