ENGINE
Consult the Engine Owners Manual for
the manufacturer's recommendations
for storage.
PUMP
The manufacturer recommends using
a pump protector/winterizer, such
as EXA80, when storing the unit
for more than 30 days and/or when
freezing temperatures are expected.
If a pump protector/winterizer is not
available, *RV antifreeze needs to be
run through the pump as outlined in
the steps below.
NOTE: Using a pump protector/
winterizer or *RV antifreeze is to provide
proper lubrication to the internal seals of
the pump regardless of temperature or
environment.
1.
Obtain a funnel, six ounces
of *RV antifreeze, and 16 - 36
inches of garden hose with a
male hose connector attached to
one end.
other antifreeze is corrosive and
can damage pump.
2.
Disconnect spark plug wire.
3.
Connect length of garden hose to
water inlet of pump.
4.
Add *RV antifreeze to hose as
shown.
A13548
STORAGE
Use only RV
antifreeze. Any
5.
Pull engine starter rope slowly
several times until antifreeze
comes out of high pressure hose
connection of pump.
6.
Remove garden hose from water
inlet of pump.
7.
Reconnect spark plug wire.
*Windshield washer fluid may also be
used
PRESSURE WASHER
1.
Drain all water from high
pressure hose, coil it, and store
it in cradle of the pressure
washer handle.
2.
Drain all water from spray gun
and wand by holding spray
gun in a vertical position with
nozzle end pointing down and
squeezing trigger. Store in gun
holder.
3.
Store chemical hose so it is
protected from damage.
4.
If space is needed, remove
handles and replace as shown.
14- ENG