The drum lid will not close.
During operation, the juicing bowl
shakes.
Layers of separation in the juice.
The drum lid is stuck.
Discoloration of the plastic parts.
Attention
► If above mentioned steps don't solve the problem, please contact your customer
service.
Caso Entsafter „Whole Slow Juicer" SJW 400
time, it may cause the juicer to stop frequently.
This can lead to pulpy juice. Insert the
ingredients slowly and few at a time.
• Make sure the juicing screw is pushed all the
way into the strainer in order for the drum lid to
close properly.
• If the juicing screw is not properly in position, the
drum lid may not close.
• The juicing screw and the strainer are set up to
crush and squeeze the ingredients. It is normal
for the juicing screw and the strainer to vibrate.
• If the ingredient contains strong fiber, the
vibration from the top-set may be stronger.
• Depending on the density of the ingredients, the
extracted juice may show layers of different
juices. It is different from separation due to
oxidation caused by juicing with a high-speed
juicer.
• After juicing, let the juicer operate for another 30
seconds to extract the remaining pulp. If there is
too much pulp lid to not open. In this situation,
press the REV(II)-O- N(I)button in this order,
switching back and forth 2-3 times.
• Pour water down the feeding tube to rinse out
the insides and then try opening the drum lid.
• After juicing, if the juicer is not cleaned right
away, the remaining pulp inside the top-set can
dry up which can make disassembling and
cleaning hard. This can also affect the juicer's
performance and color.
• Ingredients that are rich in carotenoids such as
carrots and spinach may dye the plastic parts.
When the parts are dyed with carotenoids, rub
vegetable oil into the dyed areas and use mild
detergent to clean.
• Vegetable oil should only be used during clean-
up for parts that are discolored. Do not use
vegetable oil on the juicing screw or the strainer.
If vegetable oil or oil from animal fat gets on the
juicing screw or the strainer, this can affect the
juicer's performance and may result in damaged
parts.
• The silicone pieces on the top-set can be
detached to be thoroughly cleaned.
45