Fuel gas smell
Liquid propane gas and natural gas have artificial odorants, which have been added specifically to enable the detection of fuel
gas leaks. In case of leaking gas, you will normally be able to smell the gas. Since propane (liquid gas) is heavier than air, you
will be able to smell the gas in low height near the ground.
TAKE IMMEDIATE ACTION EVERY TIME YOU SMELL GAS!!
Ÿ Do not conduct any acts that could ignite the gas. Do not operate any electric switches.
Ÿ Do not unplug any power or extension cables. Do not ignite any matches or other ignition sources. Do not use your phone.
Ÿ Ensure that all persons immediately leave the building and remove themselves from the danger zone.
Ÿ Propane gas (liquid gas) is heavier than air and can settle in low height. When suspecting a propane gas leak, stay away
from low sections.
Ÿ Use your neighbour's phone and call the fuel gas supplier and the fire brigade. No longer enter the building or the area.
Ÿ Stay outside the building and away from the danger zone until it/they have been declared safe by the fire brigade or the
gas supplier.
Ÿ Finally, have the fuel gas service technician and the fire brigade conduct a test of the leaked gas. Ensure that you ventilate
well the building or area prior to returning. Properly trained service technicians must repair all leaks, test for further leaks
and then turn device on again.
Activation
Test and ensure that AAA batteries are in the ignition chamber and that they are
charged. Ensure that the (+) anode is turned toward the outside.
The injector fitted on this appliance is not intended for removal. Injector is only
assembled by manufacturer.
This appliance is forbidden to convert from one gas pressure to another
pressure.
Do not connect the gas cylinder directly to the appliance without regulator.
The flexible hose should be approved by standard EN16436:2014.
The regulator must meet the standard EN16129:2013, the output pressure of the
regulator should match the values from the data plate.
The replaced regulator must at least correspond to the national regulations.
- Use 30mbar regulator for butane/propane under the category I3B/P(30).
- Use 30mbar regulator for butane under the category I3+(28-30/37).
- Use 37mbar regulator for propane under the category I3+(28-30/37).
- Use 50mbar regulator for butane/propane under the category I3B/P(50).
Do the following to turn of the gas heater:

Fully open the valve of the gas supply bottle.
‚ Press the control and turn to "pilot" position (ignition flame).
ƒ Press the "Igniter" button a few times in order to ignite the burner. Press for
5 seconds. Let go once burner has ignited.
„ Turn control to desired temperature position.
Ÿ Turn control to "LOW" for small flame.
See illustration
Ÿ Turn control to "HI" for small flame.
See illustration