V2 ELETTRONICA GOLD230V-D Notice D'installation page 46

Opérateur électromécanique irréversible pour portails coulissants jusqu' à 600 kg
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DISPLAY DATI
DESCRIZIONI
St.rt
Operation modes
StAn
- Start inputs from terminal board are disabled
no
- Standard operation
AP.CH
- Separated opening and closing commands
PrES
- Manned operation
oroL
- Timer operation
FrEn
no / Si
Brake function
StoP
STOP input
no
- STOP input not available
invE
- STOP command stops the gate: START command starts moving in the opposite direction
ProS
- STOP command stops the gate: pressing the START command gate continues the motion
Fot 1
PHOTO 1 input
APCh
- Input is available for the connection of the photocell
no
- Not available
Fot 2
PHOTO 2 input
CFCh
- Photocell is active in closing and also when the gate is still
no
- Not available
Ch
- Photocell is active during the closing
Ft.tE
no/Si
Photocell operational test
CoS1
no/Si
Border 1 input (fixed border)
CoS2
no/Si
Border 2 input (mobile border)
FC.En
no/Si
End of stroke inputs
ASM
0.5" ÷ 3.0"
Anti-skid function
no
- Function disabled
SEnS
0 ÷ 10
Obstacle sensor level
Cont
Counter viewing
tot.
- Total number of completed cycles (views in thousands or in units)
Man
- Number of cycles before the next request for service (such a number has been
APPr
Automatic learning of the operation time
no
- Function disabled
Go
- Start up of the automatic learning procedure
FinE
End of programming
no
- It does not exit from the program menu
Si
- It exits from the program menu by storing the setup parameters
rounded off to hundreds and it can be set up on 1000-step; in case it is set up
on 0, the request will be disabled and no will be viewed)
43
DEFAULT
MEMO
SCor
DATI
StAn
no
no
APCH
CFCh
no
no
no
Si
0.5"
5
tot
no
no