F i t t i n g a n d s e a l i n g g l a s s p a n e l s
ca. 3 cm
ca. 1 cm
Sealing glass panels
Seal grooves between glass panel and column, and
between the sealing strip and glass panel
Place sealing strip between wall profile and glass panel.
Lightly grease wedge with the enclosed silicon grease
and press it between wall profile and glass panel.
Seal groove between glass panel and wall post with
Silicon. Also put appx. 1cm of sealant between wall post
and shower tray, about 3cm from top edge of shower
tray.
Wall-version
Seal grooves between glass panels and column, and
between the sealing strip and glass panel.