M o u n t i n g w a l l l p r o f i l e , c o r n e r - v e r s i o n
Ø6
36
Mounting wall profile
Remove hexagonal nuts M12, and
washers from the bottom of the
wall profiles. Position wall profiles
with pre-assembled wall compen-
sating ledge on shower tray with
the threaded bolts through holes
and tip wall profiles against the
wall.
Corner-version
Mark the position of the wall compensating ledge on the
wall, near the shower tray rim. Now remove wall profiles
and remove the wall compensating ledge.
.
Fitting wall compensating ledge
Place the wall compensating strip along the
markings and find true vertical position with a
spirit level. Mark drill holes 6mm. Remove wall
compensating ledge, punch and drill holes, fit
dowels. Screw wall compensating ledge to the
wall using 4 cross head, round top wood screws
4x35. Check positioning (spirit level). Repeat
the same procedure on the other side.
Drill 2 holes for the installation unit. On the left
wall, appx. 70mm and 80mm from the corner and
1960 mm from the shower tray edge . Insert 2
round head wood screws 4x35. Don't tighten at
this point.