Before installation

3.1

Zone functions of SCB-10

Tab.3
Parameter setting for zone function
Zone
Parameter to set zone function
0 = Disable
1 = Direct
2 = Mixing Circuit
3 = Swimming pool
4 = High Temperature
5 = Fan Convector
6 = DHW tank
7 = Electrical DHW
8 = Time Program
9 = ProcessHeat
10 = DHW Layered
11 = DHW Internal tank
(1) The number refers to the circuit number which can be set with the rotary dial on the SCB-10.
(2) With AD249 option.
(3) The last number of the parameter is related to the zone. The code can be used to identify the parameter settings in the connection
examples.
Fig.4
Rotary dial
X2
X3
Tab.4
Zone function settings explanation
Zone setting
0 = Disable
1 = Direct
2 = Mixing Circuit
3 = Swimming pool
4 = High Temperature
5 = Fan Convector
7747028 - v.01 - 25112019
The SCB-10 with the AD249 option has following basic functions with
default zone settings:
CIRCA1 with parameter CP020 set as Direct circuit
CIRCB1 with parameter CP021 set as Disable
DHW1 with parameter CP022 set as Disable
CIRCC1 with parameter CP023 set as Disable
AUX1 with parameter CP024 set as Disable
To configure your specific installation, make sure to check and adjust the
parameter settings for the selected zones. The zone function table shows
which parameter settings are available for which zones.
CIRCA 1
CIRCB 1
(1)
CP020
CP021
(3)
x
x
x
x
x
x
x
x
x
x
x
You can use the rotary dial to identify multiple SCB-10s, for example in a
cascade situation. The default position of the rotary dial is 1. In this case
zone A will appear in the display as CIRCA1 (circuit A 1).
AD-3001318-01
Explanation
Removes the circuit display, the circuit is not used, but its pump output can be used as a
status output.
Setting to manage a heating pump on the selected zone, cooling is not possible.
Setting to manage a valve and a pump with the flow sensor, in heating or cooling (exam­
ple underfloor heating).
Setting to manage the pool heat pump according to the flow sensor (if the sensor is
present) and also the pool filter pump.
Setting to manage a pump, heats 365 days with program time, no stop in summer
Setting to manage a pump, to warm and refresh
DHW 1
(1)
(1)
CP022
(3)
(3)
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
3 Before installation
CIRCC 1
AUX 1
(1)(2)
CP023
CP024
(3)
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
en
(1)(2)
(3)
7