Introduction
Please take a few moments to carefully read
through this manual. Correct maintenance and
operation of this machine will provide the best
possible performance from your POLAR product.
Pack Contents
The following is included:
Beer Dispenser
Drip pan
Beer tower assembly
CO
line
2
Tee joint for CO
lines
2
Screws and washers
Multi-function spanner
Instruction manual
POLAR prides itself on quality and service, ensuring
that at the time of packaging the contents are
supplied fully functional and free of damage.
Should you find any damage as a result of transit,
please contact your POLAR dealer immediately.
Installation
Note: If the unit has not been
stored or moved in an upright
position, let it stand upright for
approximately 12 hours before
operation. If in doubt allow to
stand.
1. Remove the appliance from the packaging.
Make sure that all protective plastic film and
coatings are thoroughly removed from all
surfaces.
2. To optimize performance and longevity, ensure
a minimum clearance of 2.5cm is maintained
between the unit and walls and other objects,
with a minimum 5cm clearance on the top.
NEVER LOCATE NEXT TO A HEAT SOURCE.
Note: Before using the appliance
for the first time, clean the
interior with soapy water.
4
GE632-GE633_ML_A5_v1_20210423.indb 4
GE632-GE633_ML_A5_v1_20210423.indb 4
Location
The appliance is intended for indoor use only.
Be sure the location chosen has a floor strong
enough to support the total weight of the
cabinet and contents. A fully loaded unit can
weigh as much as 450kg. Reinforce the floor as
necessary to provide maximum loading.
For the most efficient refrigeration, be sure to
provide good air circulation inside and outside.
Ventilation
Be sure that the unit has access to ample air.
Avoid hot corners and locations near stoves
and ovens.
Should it become necessary to lay the unit
on its side or back for any reason, allow at
least 12 hours before start-up so as to allow
compressor oil to flow back to the sump.
Failure to meet this requirement can cause
compressor failure and unit damage.
Levelling
A level cabinet will perform better because the
doors will line up with the frames properly, the
cabinet will not be subject to undue strain and
the contents inside the cabinet will not move
around.
Use a level to make sure the unit is level from
front to back and side to side.
Units supplied with legs will have adjustable
bullet feet to make the necessary adjustments.
If the unit is supplied with castors, set the
brakes on the castors to keep the appliance in
position.
Ensure the floor where the unit is to be located
is level.
Caution:
Failure to follow all the due
installation instructions will
invalidate your guarantee.