Sanitizing Optional Sweetener - Bunn Infusion Serie Guide D'installation Et D'utilisation

Table des Matières

Publicité

All Models:
1. Remove all the quick disconnects (QCD) from all the B.I.B. containers.
2. Fill a suitable pail or bucket with a warm soapy tap water solution. (140° F)
3. Submerge all disconnects (gas and liquid) in the soapy solution and then clean them using a nylon bristle
brush. (Do not use a wire brush). Rinse with clean water.
4. Using a plastic pail, prepare approximately five (5) gallons of Kay-5 (or equivalent) sanitizing solution with at
least 100 ppm of available chlorine in 120° F water.
5. Rinse the B.I.B. disconnects (QCD's) in the sanitizing solution.
6. Special sanitizing fittings must be attached to each B.I.B. disconnect (QCD's). If these fittings are not available,
the fittings from empty B.I.B. bags can be cut from the bags and used. These fittings open the "disconnect"
so the sanitizing solution can be drawn through the disconnect opening.
7. Place all the B.I.B. disconnects (QCD's) into the pail of sanitizing solution.
Models with factory installed sweetener:
8. Press and hold the left hidden switch until the display reads: "SanitizeSweetnr?" Press "YES". Next screen will
ask "CONTAINER READY?"
9. Press "YES". Allow solution to flow from dilution nozzle for a few seconds.
10. Press any brew switch to stop. Display will read "SOAKING" and count down from 15 minutes. Display will
now read "SOAP PURGE"
11. Remove the special sanitizing fittings, or empty, cut B.I.B fittings from the B.I.B. disconnects (QCD's) and
re-connect the QCD fittings to the appropriate B.I.B. container. (You will now begin the process of bringing
syrup back through the system)
a. Place empty tea dispenser under unit
b. Place empty brew basket into funnel rails
12. Press "START". Next screen will ask "CONTAINER READY?"
13. Press "YES". Continue with brew cycle until syrup is flowing freely from the dilution nozzle.
14. Press any brew switch to stop. Display will read "SANITAION COMPLETE" and return to home screen.
Models with field installed sweetener kit:
8. The next steps are to initiate a brew cycle and draw sanitizer through the system:
a. Place empty tea dispenser under unit.
b. Place empty brew basket into funnel rails
c. Push appropriate brew button for Sweet Tea (brew cycle will initiate)
d. Continue with brew cycle until the sanitizing solution is flowing from the dilution nozzle.
e. Push the "Enable Brew on/off" button to stop the brew cycle and then push again to cancel the brew
cycle
f. Allow sanitizer to remain in lines for fifteen (15) minutes.
9. Remove the special sanitizing fittings, or empty, cut B.I.B fittings from the B.I.B. disconnects (QCD's) and
re-connect the QCD fittings to the appropriate B.I.B. container. (You will now begin the process of bringing syrup
back through the system)
a. Place empty tea dispenser under unit
b. Place empty brew basket into funnel rails
c. Push appropriate brew button for Sweet Tea (brew cycle will initiate)
d. Continue with brew cycle until syrup is flowing freely from the dilution nozzle. You may need to repeat steps
"a" through "d" until syrup is dispensing from the dilution nozzle.

SANITIZING OPTIONAL SWEETENER

12
36748.3 111010