Kronos 50 Manuel D'installation page 15

Pompe de dosage péristaltique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

 
Paragraph 7
Programming
Density
1.00 kg/L
 
Paragraph 8
Programming
Triggers
 
No Trg
 
Paragraph 9
Programming
 
Units
 
L/h
 
Paragraph 10
Programming
 
Buzzer
 
Off
 
Paragraph 11
Programming
Level Alarm
 
Stop
0000137630
 
 
 
 
 
 
 
 
 
 
 
 
 
Rev. 2.0
This makes it possible to set the density of the chemical
product.
This makes it possible to set the input triggers.
When the triggers are present, gives consent to the pump
to run, depending the setting pump function:
No Trg= the triggers are disabled.
Trg 1= the pump run when only the trigger 1 is
enabled.
Trg 2= the pump run when only the trigger 2 is
enabled.
Trg 1&2= the pump run when the both triggers
(1&2) are enabled.
This makes it possible to set unit of measurement, which
can be:
L/h= liter per hour.
ml/m= milliliter per minute.
Gph= Gallon per hour.
%= the percentage of the maximum flow-rate.
The buzzer is active when there is an alarm condition.
This makes it possible to set the buzzer the system to On
or Off.
This makes it possible to set the level alarm as follow:
Stop= the pump stops.
Run= the pump keeps running.