Programming
1:N MODE
Memory Off
 
1:N MODE
 
1:1
 
Case N:1 Mode:
Pump doses following pulses number to the related input.
N input pulses generate 1 second of dosing at 1%
e.g.
If N is set to 1 (N=1), pump doses for one second at speed=1% of Max speed
If N is set to 100 (N=100), pump waits for 100 pulses than doses for one second at speed=1% of Max
speed
version
10000ml/h
2000ml/h
* quantity dosed in 1 second
If calculated flow rate is bigger than maximum, the pump goes in MEM function (if selected) and doses the lasting
quantity when possible.
Programming
N:1 MODE
Memory Off
 
N:1 MODE
 
1:1
 
0000137630
 
 
 
 
 
 
 
Average Dosing @ 1%*
0.027ml
0.0055ml
 
 
 
 
 
 
Rev. 2.0
The pump doses in proportion to an external signal (i.e.:
impulse launch counter). With every signal received, the
pump makes 1 second at the programmed "N" (i.e.: 20%)
speed.
The value of "N" can be modified during operation, by
pressing the
the flow, or the
Makes it possible to set:
Memory= The pump has a memory function, which
signals the reception of a signal during dosage. If
set to Off, it merely sends a signal, if set to On it
sends a signal and memorizes the impulses, then
executes them when it has finished receiving
signals
1:N= With every signal received, the pump makes 1
second at the programmed "N" (i.e.: 20%) speed.
Average Dosing @ 100%*
2.77ml
0.55ml
The pump doses in proportion to an external signal (i.e.:
impulse launch counter). With every programmed "N" signal
received, the pump makes 1 second at the 1% of max
speed.
The value of "N" can be modified during operation, by
pressing the
the flow, or the
Makes it possible to set:
Memory= The pump has a memory function, which
signals the reception of a signal during dosage. If
set to Off, it merely sends a signal, if set to On it
sends a signal and memorizes the impulses, then
executes them when it has finished receiving
signals
N:1= With every programmed "N" signal received,
the pump makes 1 second at the 1% of max speed.
Operation
keys at the same time to increase
keys to decrease it.
Operation
keys at the same time to increase
keys to decrease it.
11