Thermo King SLX-100 Mode D'emploi page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
CONTROLLER DESCRIPTION
Alarms Menu
If a unit alarm condition occurs the large Alarm
Icon will appear on the Standard Display.
If an alarm specific to a zone occurs, then a
small zone alarm icon will appear next to the
affected zone as well. Both Alarm Icons will be
present.
Alarms are viewed and cleared using the Alarm
Menu as follows:
1. Start at the Standard Display.
2. Press the MENU soft key on the Standard
Display.
3. Press the NEXT soft key until the Alarm
Menu appears.
4. Press the SELECT soft key. The Alarm
Display will appear.
5. If no alarms are present, the "NO ALARMS"
Screen is shown. Press the EXIT soft key to
return to the Standard Display.
6. If alarms are present, the quantity of alarms
and the most recent alarm code number will
be shown. If there is more than one alarm,
press the NEXT soft key to view each alarm.
N.B. To clear an alarm of this kind, you
must contact your dealer.
7. If a serious alarm occurs, the unit will be
shut down to prevent damage to the unit or
the load. If this occurs, the display will show
that the unit is shut down and display the
alarm code that caused the shutdown.
8. To clear an alarm press the CLEAR soft key.
14
Allows the operator to view
Datalogger Menu
the datalogger displays. A "START OF TRIP"
places a marker in the datalogger memory. A
Start Of Trip can be initiated through the use of
WinTrac datalogging software, or manually in
the field.
1. Press the MENU soft key on the Standard
Display.
2. Press the BACK and NEXT soft keys as
required to show the Datalogger Menu.
3. Press the Select soft key on the Datalogger
Menu. The "START OF TRIP" Screen will
appear.
4. Press the Selections key. The "START OF
TRIP" Screen will appear.
5. Press the SELECT soft key to initiate a start
of trip.
6. A Start Of Trip Marker has been inserted into
the datalogger memory.
Start a Pretrip as follows:
Pretrip
1. Press the MENU soft key on the Standard
Display.
2. Press the BACK and NEXT soft keys as
required to show the Pretrip Screen.
3. Press the SELECT soft key to start a Pretrip.
4. A Full Pretrip will be initiated if the unit is
not running. If the unit is running in either
Diesel or Electric mode a Running Pretrip
will be performed.
5. The Pretrip display appears. The top line of
the display indicates the unit is performing
the non-running Pretrip. Test progress is
measured by the number of tests completed
out of a total of 49. The soft keys may be
used during the Pretrip Test to select the
Hourmeter, Gauge or Sensor menus.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Slx-200Slx-300Slx-400Slx spectrum w/sr-2

Table des Matières