Télécharger Imprimer la page

Honeywell GSS Serie Instructions D'installation page 7

Publicité

GSS Series Hinge Mount
90
Designation and
Rated Operational Current Ie (A) at Rated Operational
Utilization Category
Voltage Ue
AC15 A300
120 V
AC15 A500
AC1
A600
AC15
A600
6 A
AC15
A300
6 A
DC13
Q300
0,55 A
Gold-plated contacts
Rated Thermal Current (I
)
th
Rated Impulse Withstand (U
imp
Rated Insulation Voltage (Ui)
Maximum Fuse Rating (SCPD)
Sealing
(GSC, GSE)
(GSD)
Operating Temperature Range
Storage Temperature Range
Maximum Operating Speed
Mechanical Life
MCTF (Mechanical Life): 1,403,000 cycles
MCTF (Electrical Life): > 25,000 cycles with single-sided confidence limit of 100 %
Highest SIL Capability: SIL3 (HFT:1), IEC 61508-2: 2010
Proof Test Interval : 1 Year
Complies with: Machinery Directive 98/37/EC, IEC 60947-5-1
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship. Honeywell's
standard product warranty applies unless agreed to
otherwise by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will
repair or replace, at its option, without charge those items it
finds defective. The foregoing is buyer's sole remedy and
is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a
particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
While we provide application assistance personally, through
our literature, and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information
we supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
240 V
380 V
480 V
3 A
1,9 A
1,5 A
3 A
0,27 A
1 V, 10 µA min; 50 V, 100 mA max.
10 A
)
2500 V
300 V, 500 V, 600 V
10 A Quick Acting
IP66; Enclosure Type 1, 4, 12, 13
IP66/IP67; Enclosure type 1, 4X (indoor use only), 12, 13
-25 °C to 85 °C (-13 °F to 185 °F)
-40 °C to 85 °C (-40 °F to 185 °F)
100 operations/minute
1,000,000
90
Switch Version
500 V
600 V
1,4 A
1,2 A
GSD
GSC, GSE
GSC, GSD, GSE
GARANTÍA/REMEDIO
Honeywell garantiza que los productos que fabrica están
libres de materiales defectuosos y fallas de mano de obra.
Se aplicará la garantía de producto estándar de Honeywell's
a menos que Honeywell acuerde lo contrario por escrito;
consulte el acuse de recibo o póngase en contacto con su
oficina local de ventas para obtener los detalles de la
garantía específica. Si se devuelven a Honeywell productos
garantizados durante el período de cobertura, Honeywell
reparará o reemplazará sin cargo, siempre que lo considere
oportuno, aquellos productos que determine que presentan
defectos. Lo expuesto en el punto anterior sustituye a
cualquier otra garantía, sea explícita o implícita,
incluyendo garantías comerciales y de idoneidad para
un propósito específico. En ningún caso Honeywell se
hará responsable de cualquier daño derivado, especial o
indirecto.
Si bien proporcionamos asistencia para la aplicación en
forma personal, a través de nuestra bibliografía y del sitio
Web de Honeywell, queda a criterio del cliente determinar la
aptitud del producto en la aplicación.
Las especificaciones pueden variar sin aviso. La información
suministrada es considerada correcta y fiable en el momento
de esta impresión. No obstante, no asumimos la
responsabilidad por su uso.
Honeywell Sensing and Productivity Solutions
PK 80138
Issue 7
90
90
7

Publicité

loading

Ce manuel est également adapté pour: