7. INSTALL, CONDITION AND FLUSH FILTER CARTRIDGE
Align the filter cartridge lug with the filter head and push
upwards into the head.
Turn filter cartridge to the right until rotation stops (about
1/4 turn).
T. Place the drain line into a bucket.
U. Make sure the flush shut-off valve is in the CLOSED position.
V. Turn the cold line water pressure ON, OPEN the angle stop
valve to flow.
W. OPEN the faucet and leave open. You will get no or very little
flow through the cartridge.
X. CLOSE the angle stop valve.
Y. OPEN the flush shut-off valve. Water and air should forcibly
exit the system through the drain line and into the bucket.
Z. Repeat steps V-Y until steady flow exits the faucet (about
three to five times).
Now that flow has been established, the filter cartridge can be
flushed. Flush for five minutes at full flow. Flushing will remove
carbon fines and trapped air.
NOTE:
Purging air from water lines with low pressure may require
several additional minutes of flushing.
For fresher water it is recommended that you run the tap at least
20 seconds prior to using water for drinking or cooking purposes.
Initially, filtered water may appear cloudy. If you set a glass
of water on a level surface, you should be able to watch the
cloudiness disappear from the bottom of the glass upwards.
This harmless cloudiness results from the release of trapped air
within the filter cartridge and will disappear within a few days
after installation.
8. INSTALL DECORATIVE COVER
Installation is complete.
9. INSTALL EVERPURE FILTER TIMER
Remove plastic wrapper and pull tab from back of Everpure Filter
Timer. The LED and buzzer will cycle 3 times to confirm the start. It
is programmed to flash/sound again in 11 months. Remove adhesive
backing and mount Timer in a convenient location under the sink.