Specifications - Beha-Amprobe EV-500 Serie Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59

SPECIFICATIONS

General Features
Input voltage
EVC-20 Test Cable
EVC-13 Test Cable
Dimensions (W × H × L)
Weight
IP-rating
CE directive
Safety
EMC
Working temperature range
Storage temperature range
Reference humidity range
Working humidity range
Pollution degree
Protection class
Measurement category
Altitude above sea level
Functions
PE Pre-Test
PP Simulation
CP States
CP Error "E"
PE Error (Earth fault)
Outputs (for test purpose only)
Measuring terminals
L1, L2, L3, N and PE
Mains socket
Mains socket protection
CP Signal output terminals
Up to 250 V (single phase system) / up to 430 V (three phase system),
50/60 Hz, max 10 A
AC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed
cable with vehicle connector (type 2, 7P three-phase)
AC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with
vehicle connector (type 1, 5P single-phase)
110 × 45 × 220 mm (length without connection cable and test cable)
Approx. 1 kg
IP54
Low Voltage Directive LVD 2014/35/EU
IEC/EN 61010-1:2010
IEC/EN 61010-2-030:2010
Not applicable
0 ... +40 °C
-10 ... +50 °C
10 ... 60% relative humidity w/o condensation
10 ... 85% relative humidity w/o condensation
2
II
CAT II 300 V
2000 m max.
Yes
Open, 13 A, 20 A, 32 A, 63 A
A, B, C, D
On/off
On/off
Max. 250/430 V, CAT II 300 V, max. 10 A
Max. 250 V, CAT II 300 V, allowed current max. 10 A,
Note: Do not load mains socket simultaneously with measuring terminals!
Fuse T10A/250V, 5×20 mm, type 179200 produced by Siba
Approx. +/-12 V, CAT 0 (under normal condition)
In case of wrong wiring or error of the charging station these terminals
may become hazard => up to max. CAT II 300 V against PE