2.10 Main connection

The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. Sau-
na heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type.
Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC
insulated cable as a connection cable for the sauna heater.
A multipolar (e.g. 7-pole) cable is allowed, if the voltage is the same. In the absence of a separate control current fuse, the
diameter of all cables must be the same, i.e. in accordance with the front fuse.
The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater.
The maximum height for the connection box is 500mm from the floor.
If the connection box is located at 500mm distance from the heater, the maximum height is 1000mm from the floor. (Image
3 on page 11: Location for the connecting box).
Sauna heater insulation resistance: The sauna heater heating elements may absorb moisture from air, e.g. during storage.
This may cause bleeder currents. The moisture will be gone after a few heating sessions. Do not connect the heater power
supply through a ground fault interrupter.
However, always adhere to the effective electrical safety regulation when installing the sauna heater.
Heater connection
cable H07RN-F/
Effect
60245 IEC 66
mm
400-415V 3N~
6,0
5 x 1,5
8,0
5 x 2,5
Table 2 Connection cable and fuse
Fuse
Heater connection
cable H07RN-F/
60245 IEC 66
2
A
3 x 10
3 x 16
Fuse
2
mm
230V 3~
A
4 x 2,5
3 x 16
4 x 6
3 x 25
Heater connection
Fuse
cable H07RN-F/
60245 IEC 66
2
mm
230-240V 1N~ / 2~
A
3 x 6
1 x 35
3 x 6
1 x 35
10