Electrical Connections And Equipotential Bonding (Mod. Bm1G160I / Bm1G200I And For All The Versions Motorized Bas00 - Firex 900 Serie Manuel D'installation, D'entretien Et D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.2.1. ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL
(MOD. BM1G160I / BM1G200I AND FOR ALL THE
BONDING
VERSIONS MOTORIZED BAS00... )
Warning! :
The appliance is supplied to operate according to the power supply
indicated on the data plate.
 As mentioned, the appliance must be connected to the power supply by way of a
multiple pole main isolating switch and protection device that must be proportioned to
the power of the appliance (1 mA per kW of rated power).
 The earthing system must be efficient.
 As this appliance is a type X equipment (delivery without power cable and plug), the
cable and other hardware needed to make the connection to the electrical power
supply must be provided by the installer.
 The power cable shall be of the kind described in the paragraph "Technical data" and
shall be resistant to oil.
Proceed as follows to reach the power supply terminal board:
-
Disconnect the appliance using the switch placed before the appliance.
-
Remove the fron panel, unloosing the two fixing screws.
Remove the lid of the housing protecting the electrical components.
 The cable must be fed in from beneath the clamp. The individual wires are then
fastened to the corresponding terminals of the terminal board. The earth wire must be
longer than the other wires, so that in case of the cable being tugged or the clamp
broken, the live wires will disconnect first. Lock the cord fastener.
 The appliance must incorporate an equipotential system.
 Connect the terminal on the lower right-hand side marked with the international symbol a
connector with a nominal cross section <10 mm
system of the building shall be connected like this.
It's strictly forbidden using the pending electric cable connected with terminal board,
overhanging from the frame, to connect definitely the machine.
ATTENTION!
Cut the tension before to make the connection and/or maintenance .
Instruction manual for installation, maintenance and use
GAS TILTING BRATT PANS Serie 900 BM.G080-200
2
. All the appliances installed and the earth
- GB -
12 di 40
Page

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bm8g080Bm9g090Bm1g120Bm1g150Bm1g160iBm1g200i

Table des Matières