Firex 900 Serie Manuel D'installation, D'entretien Et D'emploi page 46

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Table 1
Model
Outer
dimensions
cm
BM8G080 80X90X90
BM9G090 90X90X90
BM1G120 120X90X90
BM1G150 120X90X95
BM1G160I 160X90X90
BM1G200I 160X90X95
Table 2 – Electrical data – (version not motorized)
Specifications
Description
Power
Voltage/Input
Power cable
Table – Electrical data – (version motorized)
Specifications
Description
Power
Voltage/Input
Power cable
Instruction manual for installation, maintenance and use
GAS TILTING BRATT PANS Serie 900 BM.G080-200
1.2. TECNICAL DATA
Qn
Gas
connection
kW
R ½"
22
R ½"
22
R ¾"
30
R ¾"
30
R ¾"
42
R ¾"
42
Unit of measurement
kW
2
mm
Unit of measurement
kW
2
mm
G a s p a r t
G20
H i = 9,45
kWh/m³
m³/h
2,3
2,3
3,2
3,2
4,5
4,5
Model
BM1G160I / BM1G200I
0,4
AC 230 V / 50 Hz
3 x 1,5
Model
BAS00...
0,09
AC 230 V / 50 Hz
3 x 1,5
- GB -
G30
H i = 12,68
kWh/kg
kg/h
1,73
1,73
2,3
2,3
3,3
3,3
6 di 40
Page

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bm8g080Bm9g090Bm1g120Bm1g150Bm1g160iBm1g200i