Installation / Operation
Hazardous voltage. Can shock, burn or
cause death. To reduce the risk of electric shock, pull
the plug before servicing. This pump has not been
investigated for use in swimming pool areas. The
pump is supplied with a grounding conductor and
grounding-type attachment plug. Be sure it is con-
nected only to a properly grounded grounding-type
receptacle. Keep extension cords and all plugs dry.
Where a 2-prong wall receptacle is encountered, it
must be replaced with properly grounded 3-prong
receptacle installed in accordance with the codes
and ordinances that apply.
Do not walk on wet area until all power has been
turned off. If the shut-off box is in the basement, call
the electric company or hydro authority to shutoff
the service to house, or call your local fire depart-
ment for instructions. Failure to follow this warning
can result in a fatal electrical shock.
Do not lift the pump by the power cord.
13. All wiring should be performed by a qualified
electrician.
14. Make certain the power source conforms to the
requirements of your equipment.
15. Protect the electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immediately.
16. Do not touch an operating motor. Modern motors
can operate at high temperatures.
17. Do not handle the pump or the pump motor, or
change fuses with wet hands or when standing on
wet or damp surface, or in water.
INSTALLATION
1. Set the pump on a hard surface in at least 2 inches
of water.
2. Connect the discharge line with the fittings provided.
3. The pump should not be installed on clay, dirt, mud
or sand surfaces. Although the pump will usually
pass small particles suspended in water, clean the
area to be pumped of small stones and gravel which
could clog the pump.
*NOTICE: Grass, mud, sand or pea gravel can clog the
pump and reduce it's performance. Keep the pump inlet
screen clean.
4. To reduce motor noise and vibrations when using
rigid pipe, a short length of rubber hose (e.g. radiator
hose) can be connected into the discharge line near
the pump using suitable clamps.
5. Power Supply: These pumps are designed for 115 V.,
60 Hz., operation and requires a minimum 15 amp
individual branch circuit. Pump is supplied with a
3-wire cord with grounding-type plug.
For parts or assistance, call SHUR-DRI Customer Service at
Hazardous voltage. Can shock, burn or
cause death. Pump should always be electrically
grounded to a suitable electrical ground such as a
grounded water pipe or a properly grounded metallic
raceway, or ground wire system. Do not cut off
round ground pin.
6. If the pump discharge line is exposed to an outside
sub-freezing atmosphere, the portion of line exposed
must be installed so any water remaining in the pipe
will drain to the outfall by gravity. Failure to do this
can cause the water trapped in the discharge to
freeze which could result in damage to the pump.
7. Check the system operation by observing the pump
operation through one complete cycle.
Risk of flooding. Failure to make this
operational check may lead to improper operation,
premature failure, and flooding.
OPERATION
Hazardous voltage. Can shock, burn or
cause death. Do not handle a pump or pump motor
with wet hands or when standing on wet or damp sur-
face, or in water.
Before attempting to check why a unit has stopped oper-
ating, disconnect power from the unit.
1. The shaft seal depends on water for lubrication and
cooling. Do not operate the pump unless it is sub-
merged in water as seal may be damaged if allowed
to run dry.
.3
Figure 1: Typical uses for pump
1-800-535-4950
Dewater flat roofs
Roofs
Empty flooded rooms
Basements
.3