Télécharger Imprimer la page

Technical Specifications; Electrical Connections - Dea 212E Notice D'emploi Et Avertissements

Armoire de commande programmable
Masquer les pouces Voir aussi pour 212E:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

3 TECHNICAL SPECIFICATIONS

Power voltage (V)
Flashing output 230V
Auxiliary power output (24Vaux)
Safety power output (24Vsic)
Max motor power
Fuse F1
Fuse F2
Operating temperature limit
Radio receiver frequency
Max. no. radio controls managed

4 ELECTRICAL CONNECTIONS

Complete the electrical connections following the indications in "Table 1" and the diagram on page 49-50.
WARNING Connect to the 230V ~ 50 Hz mains using an omnipolar switch or other device that ensure omnipolar mains cut-off, with a
3,5 mm contact opening distance.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
1-2
Power input 230 V ~ - 50Hz (L = phase, N = neutral)
3-4
Flashing output 230 V ~ 50 Hz max 40W
5-6-7
Motor output 2 max 500W (5 = open, 6 = shared, 7 = closed)
8-9-10
Motor output 1 max 500W (8 = open, 9 = shared, 10 = closed)
Output 24 V ~ controlled safety device power. To be used for TX photocell and safety device power when checking their
11-13
operations at the beginning of every manoeuvre.
Output 24 V ~ auxiliary and uncontrolled safety device power. To be used for auxiliary device, RX photocell (in any case) and
12-13
safety device power when checking their operations at the beginning of every manoeuvre.
WARNING operations with 1 motor: N.C. input closing limit switch.
If not used, short circuit to terminal no. 19
14
WARNING operations with 2 motors: Input not used, short circuit to terminal no. 19
WARNING operations with 1 motor: N.C. input opening limit switch.
If not used, short circuit to terminal no. 19
15
WARNING operations with 2 motors: N.C. input external safety device. If triggered it reverses drive.
If not used, short circuit to terminal no. 19
N.C. input external safety device. If triggered it reverses drive.
16
If not used, short circuit to terminal no. 19
N.C. input photocell. If triggered during closing, it reverses drive.
17
If not used, short circuit to terminal no. 19
N.O. input start. If triggered, it opens or closes. It can operate in "reverse" or "jog" mode. It can also be used to connect a
18
timed contact.
19
Shared inputs
20
Antenna signal
21
Antenna grounding
8
230 V ~ max 75mA art. LED230AI
24 V ~ max 200mA (24Vaux + 24Vsic)
433,92 MHz rolling code encoding/dipswitch
Table 1 "terminal board connection"
230V ~ ±10% (50Hz)
2 x 500W max
T5A 250V delayed
T100mA 250V delayed
-20÷50 °C
30

Publicité

loading