The pellets used must comply with the features described by
the Standard:
Š en pLuS - uni en 16961 - 2 classe A1 -A2
Š Ö-nOrM M 7135
Š Din pLuS 51731
Dal Zotto recommends the use of pellets with
a 6 mm diameter for its products.
open the tank lid and load the pellets using a scoop.
tHe uSe OF expireD peLLetS Or Any OtHer MAteriAL DAMAgeS tHe FunctiOnS OF yOur StOve AnD cAn
DeterMine tHe invALiDity OF tHe WArrAnty AnD tHe AnnexeD reSpOnSiBiLity OF tHe MAnuFActurer.

HOt Air Ducting

Š The pipe destined for ducting the hot air must have an internal diameter of 80 mm, be insulated and protected from heat loss.
Š The length must not exceed 6 metres.
Š installation of the pipes used for ducting the hot air must be performed by qualified staff and/or the manufacturer's
technical after-sales assistance.
FOr tHiS prODuct it iS MAnDAtOry tO Duct tHe HOt Air.
it iS nOt pOSSiBLe tO DeActivAte tHe Ducting MOtOr.
DO nOt cOver Or cLOSe Ducting!
Ducting OF tHe ritA eLite MODeL cAnnOt Be ADjuSteD. By DeFAuLt itS FunctiOning iS pArALLeL tO FrOnt
ventiLAtiOn. See tHe FOLLOWing cHApter FOr itS MAnAgeMent.
44
ritA eLite
engLiSH
The ducting extension is found in the
accessory pack inside the stove.
It is mounted by means of the 4 supplied screws.