Electrical Connections - Ferroli EGEA 90LT Manuel D'utilisation, Installation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EGEA
90LT - 120LT
5.5.1 Condensate drain connection
The condensate forming during heat pump operation flows
through a special drain pipe (½") that runs inside the insulation
casing and comes out the bottom of the equipment (fig. 13). It
must be connected to a duct so that the condensate can flow
regularly (see installation example fig. 16 and fig. 17).
fig. 16 - Example of condensate drain connection without a trap
fig. 17 - Example of condensate drain connection with a trap
60mm
cod. 3541T580 - Rev. 03 - 05/2020

5.6 Electrical connections

The product comes already wired for the mains supply. It is pow-
ered via a flexible cable and a combination plug/socket (fig. 18
and fig. 19). For connection to the mains, a Schuko socket with
ground and separate protection is required.
ATTENTION!: The power supply line to which the
equipment will be connected must be protected
by a suitable differential switch.
The type of differential must be chosen accord-
ing to the type of electrical devices used by the
overall plant.
For the mains connection and the safety devices
(e.g. differential switch), comply with IEC stan-
dard 60364-4-41.
fig. 18 - Schuko socket
fig. 19 - Unit plug
83
EN