Expected Humidity Performance Coverage in Square Feet Based on Construction Type
Model No.
GPD
Elite 570
12
17
Elite 900
18
Elite 1000
Outside Design Temp
Outside Design R.H.
Inside Design Temp.
Inside Design R.H.
Air Changes/hour (AC/H)
Ceiling Height
Furnace Plenum Temp.
Furnace run time for
calculating sq. ft.
16-1/2"
HUMIDIFIER PACKAGED COMPONENT ACCESSORIES
Model 1000A (GFI#5730) includes:
Humidi er components: GA19 Vapor pad, Solenoid Assembly, Relay Circuit Board, Fan Motor, Fan Blades
Accessories: GFX3 Automatic Digital Humidistat, Code Valve, Saddle Valve
Model 1000M (GFI#5735) includes:
Humidi er Components: GA19 Vapor Pad, Solenoid Assembly, Relay Circuit Board, Fan Motor, Fan Blades
Accessories: Manual Humidistat, Saddle Valve
ELITE 1000 HUMIDIFIER SPECIFICATIONS
Loose (0.75 AC/H)
800 sq. ft.
1115 sq. ft.
1175 sq. ft.
Humidifier Performance Baseline Criteria
16-3/4"
Average (0.50 AC/H)
1200 sq. ft.
1650 sq. ft.
1770 sq. ft.
0° F (-18° C)
70% R.H.
70° F (21° C)
30% R.H.
0.30
8 ft
120° F (49° C)
8hr/1 day
17"
12-1/8"
Humidi er Chassis with plenum
Tight (0.30 AC/H)
2000 sq. ft.
2800 sq. ft.
3000 sq. ft.
14-1/8"
cut out shown as dashed lines