Whether or not to run temperature compensation is determined in set-up mode.
If the T-sensor is present when in set-up mode, then temperature compensation
is automatically activated. If the charger does not detect the temperature
sensor during set-up mode, then the charging program will run normally.
Activating the sensor
Attach the temperature sensor to the designated connector at the front of the
charger. Next, set the charger to set-up mode (see chapter Setting the charger.
This can be done at the same time as choosing the charge setting). The orange
LED light for 'charge process' will illuminate, indicating that the charger has
detected the presence of the temperature sensor and will apply temperature
compensation to the charging voltage. The presence of the temperature sensor
is saved in the charger's memory.
If you don't want to use the T-sense any longer, then you need to remove the
temperature sensor and run the charger set-up mode again. The charger will
not detect a sensor (orange LED remains switched off), which means that
charging will not be temperature compensated.
Temperature sensor protection
If the charger is set for the T-Sense1, but during use the charger fails to detect
the sensor, then the charger will stop charging and the red 'power' LED will
illuminate.
If the temperature sensor has not been activated, but while in use the charger
detects the temperature sensor, then the charging process will stop and the red
'power' LED will illuminate. In the event of any other errors, such as incorrect
measurements, etc., the charging process will stop and the red 'power' LED will
illuminate.
If the fault is settled, the charger must be reset (by means of the main power or
stand by function)
INSTALLATION
The atmosphere
The battery should be charged in an area with adequate ventilation because it
may emit explosive gases. Be sure that there is enough space around the
charger. This is important for the air circulation, for cooling of the charger and
release of gases emitted. The LBC 500S may not be used outdoors.
Important
Don't not charge when there is a fuel leak or fuel is evaporating.
Mounting
The charger can be mounted in different ways (preferably vertically) with the
mounting plate on the bottem of the charger. Place the charger on a stabile
underground.