Facom NU-711A Manuel D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
DC Voltage
Range
Resolution
400mV
0.1mV
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Input Impedance:
the range 400mV: >1000MΩ / the other ranges: 10MΩ
Overload Protection: 600V DC/AC rms
AC Voltage
Range
Resolution
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Input Impedance:
10MΩ
Frequency Range:
40Hz -400Hz
Response:
Average, calibrated in rms of sine wave
Overload Protection: 600V DC/AC rms
DC Current
Range
Resolution
400µA
0.1µA
4000µA
1µA
40mA
0.01mA
400mA
0.1mA
4A
0.001A
10A
0.01A
Overload Protection: Fuse 1 : F 400mA/690V - Fuse 2: F 10A/690V
Max. Input Current: 10A ( For inputs > 2A : measurement duration
< 10 secs, interval > 15 minutes )
Max. Measurement Voltage Drop: 400mV
Note: The 10A range is specified from 20% to 100% of range.
AC Current
Range
Resolution
400µA
0.1µA
4000µA
1µA
40mA
0.01mA
400mA
0.1mA
4A
0.001A
10A
0.01A
18
Accuracy
± (1.0% + 5)
± (0.8% + 3)
± (1% + 5)
Accuracy
± (1.0% + 5)
± (1.2% + 5)
Accuracy
± (1.2% + 3)
± (1.5% + 3)
± (1.8% + 3)
± (2.0% + 5)
Accuracy
± (1.5% + 5)
± (1.8% + 5)
± (2.0% + 5)
± (2.5% + 10)

Publicité

Table des Matières
loading

Table des Matières