General Specification - Facom NU-711A Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Symbol Meaning .
Continuitytest is selected.
Diode test is selected.
Data Hold is enabled.
Relative mode is active.
AC
DC .
Negative sign
Battery is low and should be replaced immediately
Autorange mode is selected.
Auto Range
10. Units on the LCD
mV, V
Voltage unit
mV: Millivolt ; V: Volt 1V=10
3
mV
ɥA, mA, A
Current unit
ɥA: Microamp; mA: Milliamp; A: Ampere 1A = 10
Ω, kΩ, MΩ
Resistance unit
Ω : Ohm; kΩ : Kilohm; MΩ : Megohm; 1MΩ =10
nF, ɥF
Capacitance unit
nF : Nanofarad; ɥF : Microfarad 1F=10
Hz, kHz, MHz
Frequency unit
Hz: Hertz; kHz: Kilohertz; MHz: Megahertz 1MHz=10
Unit of duty cycle
%
% : Percent

GENERAL SPECIFICATION

Display: 3 3/4-digit LCD, with a max. reading 3999
Overrange Indication: "OL" shown on the display
Negative Polarity Indication: negative sign "
Sampling Rate: 2 -3 times/sec
Operating Environment: 0°C ~ 40°C, < 75%RH
Temperature Coefficient: 0.2 x (specified accuracy)/°C (< 8°C or > 28°C)
Storage Environment: - 10°C ~ 50°C, <85%RH
Operating Altitude: 0 to 2000 meters
Battery: 9V, 6F22 or equivalent, 1 piece
Low Battery Indication: "
" shown on the display
Size: 203x105x55mm
Weight: about 460g (including battery)
SPECIFICATIONS
Accuracy is specified for a period of one year after calibration and at 18°C to 28°C, with
relative humidity < 75%.
Except where specified specially, accuracyis specified from 8% to 100% of range.
17
ɥA
3
mA = 10
6
Ω
3
kΩ =10
6
ɥF=10
nF=10
pF
6
9
12
3
kHz=10
6
Hz
" shown on the display automatically

Publicité

Table des Matières
loading

Table des Matières