Section 1. Safety Information; For Your Safety - Jandy BWVL-SLD Manuel D'installation Et De Fonctionnement

Soupape à tiroir et soupape de lavage à contre-courant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy

Section 1. Safety Information

FOR YOUR SAFETY: This product must be installed and serviced by a professional pool/spa service technician.
The procedures in this instruction sheet must be followed exactly. Improper installation and/or operation may void
the warranty.
Ensure that all electrical power to the system is turned off before approaching, inspecting or troubleshooting any
leaking valves that may have caused other electrical devices in the surrounding area to get wet. Failure to do so
could result in an electrical hazard that could result in death or serious injury due to electrical shock, and may also
cause damage to property.
• Do not connect system to an unregulated city water system or other external source of
pressurized water producing pressures greater than 35 PSI.
• Pressurized air in system can cause product failure or also cause the filter lid to be blown off
which can result in death, serious personal injury, or property damage. Be sure all air is out
of system before operating or testing the equipment.
To minimize risk of severe injury or death the filter and/or pump should not be subjected to the
piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These
requirements are generally not intended to apply to the pool equipment such as filters or pumps.
Jandy pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system must include
the filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed
and secured before testing.
• RELEASE ALL AIR in the system before testing.
• AIR PRESSURE MUST NOT be used for pressure testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult equipment
manufacturer.
Never run the pump without water. Running the pump "dry" for any length of time can cause severe damage to both
the pump and motor and may void the warranty.
To avoid risk of damage or injury, verify that all power is turned off before starting this procedure.
Slide Valve & Backwash Valve
®
WARNING
WARNING
CAUTION
READ AND FOLLOW ALL INSTRUCTIONS
|
Installation & Operation Manual
WARNING
WARNING
WARNING
Page 3
ENGLISH

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bwvl-sld-75Svlv8Svlv2

Table des Matières