Nickel-Metal-Hydride (Ni-Mh) Charge Programs - GRAUPNER ULTRA TRIO PLUS 16 Instructions D'utilisation

Chargeur rapide à grande puissance piloté par micro-processeur pour la charge rapide, la décharge et le cyclage des accus nicd, nimh, lipo/liio/limn/life et des accus pb
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NiCd-Delta-Peak (- Peak) trigger voltage
N i C d
d e l t a - p e a k -
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2 sec.
N i C d
d V
=
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+
INC
This in turn causes the battery voltage to fall slightly (Delta-V). The charger detects and assesses the
voltage decline.It is possible to adjust the sensitivity, or trigger voltage (in mV per cell!) of the automatic
cut-off circuit for Ni-Cd batteries. A practical range of values has proved to be 10 ... 30 mV / cell. Higher
voltages often lead to overcharging of the battery, whereas a lower voltage tends to result in premature
termination of the charge process. We recommend that you check the information supplied by your
battery manufacturer, then carry out a series of test charges to establish the optimum value for your
battery. Start with 10mV/cell to avaid overcharging the battery.
NiMH
MODE
AUTOMATIC-
program
MODE
(2 sek.)
A set of convenient charge programs for recharging Nickel-Metal-Hydride batteries, as commonly used
for modelling purposes. When the charge / discharge program is fi nished, the screen displays the name
of the charge program alternating with the message „END", together with the charge time, the last
(dis-) charge current, the charged-in (discharged) capacity and the battery voltage, and continues to
do so until you disconnect the battery. This information can often give you a useful indication about the
Ni-MH pack's charge characteristics and capacity, or warn you if the charger has incorrectly assessed
the pack as being „full".
N i M h
a u t o m a t i c
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2 sec.
N i M h - A u t o
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+
-
INC
DEC
38
The automatic charge termination circuit
(battery full detection) works on the proven
Delta Peak principle (also known as the
Delta-V process), which is already in use
in millions of chargers.
This process analyses the voltage peak of
1 0 m V / C
the charge curve, which indicates with great accuracy when the
maximum charge capacity is reached.When the charge process
is started the battery voltage initially rises continuously, but as
-
the pack approaches full capacity it begins to heat up.
DEC
12. NIMh-programs (Output 1)
NiMH
MODE
MANUAL-
program
NiMh automatic program
In this program the charger detects the type of Ni-MH battery
connected to it, and adjusts the charge current accordingly to
avoid overcharging the pack.
The maximum charge current can be set before you connect
the battery to be charged.
Never use a maximum charge current higher as the value
described in the battery instruction, never higher as 2C!
Never charge transmitter batteries with more as 2 A! f. e. a 4.2
Ah battery should be limited to max. 4.2 A.
<
2 . 5 A
This is done using the INC / DEC buttons; the range available
is 0.1 A to 10 A.
The charge process is terminated auto-matically in accordance
with the values already set for „Ni-MH Delta Peak cut-off
voltage".
NiMH
NiMH
MODE
discharge
cycle
program
program
charging time
NiMH
MODE
MODE
discharge balancing
program
NiMH
MODE

delta-peak
trigger voltage

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6469Ultra trio plus 146466

Table des Matières