System Setup; Ir Setup - Leviton 41920-CP8 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

41920-CP8

System Setup

The 8-Button Control Panel works in conjunction with the Autoswitching Wallplate. The LEARN
button and the USB port referenced below are on the Autoswitching Wallplate. The buttons are
referenced using the schema in the diagram below.

IR Setup

1. Press and hold button 1 until the blue button light goes out
2. Press and hold button 4 (button 1 will also light up) until all the Control Panel buttons light up
3. Press the LEARN button on the Autoswitching Wallplate momentarily. The Control Panel is
now ready for setup
NOTE: If the LEARN button is not pressed within 60 seconds, the Autoswitching Wallplate will
return to normal operation
4. Press one of the top 4 buttons that you wish to load with an IR command. The button selected
will flash while the other buttons remain lit.
NOTE: Only buttons 1, 2, 5, and 6 should be loaded with IR commands. Buttons 3, 4, 7, and 8
have dedicated functions they perform
5. Aim the remote control that came with the display device at the IR IN on the Autoswitching
Wallplate
6. Press and hold the button on the remote control that you wish to program. When the IR code
has been learned the button on the Control Panel will stop flashing
7. You may now repeat setup steps 4 – 6 for the other buttons on the Control Panel.
8. If the wrong IR code is learned into the system, simply repeat steps 4- 6 and press the correct
button on the remote control
9. Once all buttons are programmed, press and hold button 8 until all the buttons go dark to exit
setup mode
NOTE: If no button is pressed after 60 seconds, the system will exit setup mode automatically and
save any IR codes that were learned
1
5
2
6
3
7
4
8
9
DI-060-41920-25A

Publicité

Table des Matières
loading

Table des Matières